Mini screw Application in Contemporary Orthodontic a Review of Literature

Authors

  • Zaid Abdulhussein Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author
  • Mohammed Abbood Al-Maliky Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author
  • Riyam Haleem Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author
  • Raina Ehsan Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author
  • Tuqa Shihan Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author
  • Zaid ADILBAYEV Department of dentistry, Al-Hadi University College, Baghdad-10011, Iraq. Author

Keywords:

Orthodontics, Mini Screw, Anchorage, Implants, Orthodontic Movement.

Abstract

Adequate anchoring is frequently difficult to achieve in orthodontics and dentofacial orthopaedics, particularly because many of the numerous methods established for enhancing anchorage rely on patient cooperation. The advent of skeletal anchorage with mini-screw implants, which is extensively employed in orthodontic treatments for increasing the border of tooth movement and has no patient compliance restrictions, has been a significant advancement in orthodontic therapy in recent years. The mini screw implant is only intended to be used as a temporary anchorage device. During space closure, it employs both direct and indirect anchorage. Direct anchorage is the movement of teeth utilizing orthodontic micro screw implants, whereas indirect anchorage is the stabilization of specific teeth in the dental arch and subsequent use of these stabilized anchors to move other teeth. 

Downloads

Download data is not yet available.

References

ALASSY, H., PARACHURU, P. & WOLFF, L. 2019. Peri-Implantitis

Diagnosis and Prognosis Using Biomarkers in Peri-Implant

Crevicular Fluid: A Narrative Review. Diagnostics (Basel),9.

BAYAT, E. & BAUSS, O. 2010. Effect of smoking on the failure rates of

orthodontic miniscrews. J Orofac Orthop,71,117-24.

CHANG, H. P. & TSENG, Y. C. 2014. Miniscrew implant applications

in contemporary orthodontics. Kaohsiung J Med Sci,30, 111-5.

CHEN, Y., KYUNG, H. M., ZHAO, W. T. & YU, W. J. 2009. Critical

factors for the success of orthodontic mini-implants: a systematic

review. Am J Orthod Dento facial Orthop,135, 284-91.

CHEN, Y. H., CHANG, H. H., CHEN, Y. J., LEE, D., CHIANG, H. H. &

YAO, C. C. 2008a. Root contact during insertion of miniscrews for

orthodontic anchorage increases the failure rate: an animal study.

Clin Oral Implants Res, 19, 99-106.

CHEN, Y. J., CHANG, H. H., LIN, H. Y., LAI, E. H. H., HUNG, H. C. &

YAO, C. C. J. 2008b. Stability of miniplates and miniscrews used for

orthodontic anchorage: experience with 492 temporary anchorage

devices. Clinical oral implants research, 19, 1188-1196.

CHUANG, S. K., TIAN, L., WEI, L. J. & DODSON, T. B. 2001. KaplanMeier analysis of dental implant survival: a strategy for estimating

survival with clustered observations. J Dent Res,80, 2016-20.

COGAN, J. S. 2018. A Qualitative Assessment of Invisalign® Techniques

that Experienced Clinicians Employ to Manage Extraction, Vertical,

and Transverse Plane Difficulties.Temple University. Libraries.

CORNELIUS, C. P. & EHRENFELD, M. 2010. The Use of MMF Screws:

Surgical Technique, Indications, Contraindications, and Common

Problems in Review of the Literature. Craniomaxillofac Trauma

Reconstr, 3, 55-80.

COSTELLO, B. J., RUIZ, R. L., PETRONE, J. & SOHN, J. 2010.

Temporary skeletal anchorage devices for orthodontics. Oral

Maxillofacial SurgeryClinics,22, 91-105.

DEGUCHI, T., YABUUCHI, T., HASEGAWA, M., GARETTO, L. P.,

ROBERTS, W. E. & TAKANO-YAMAMOTO, T. 2011.

Histomorphometric evaluation of cortical bone thickness

surrounding miniscrew for orthodontic anchorage. Clin Implant

Dent Relat Res, 13, 197-205.

FREUDENTHALER, J. W., HAAS, R. & BANTLEON, H. P. 2001.

Bicortical titanium screws for critical orthodontic anchorage in the

mandible: a preliminary report on clinical applications. Clin Oral

Implants Res, 12, 358-63.

GRAF, S., VASUDAVAN, S. & WILMES, B. 2018. CAD-CAM design

and 3-dimensional printing of mini-implant retained orthodontic

appliances. Am J Orthod Dentofacial Orthop, 154, 877-882.

HYDE, J. D., KING, G. J., GREENLEE, G. M., SPIEKERMAN, C. &

HUANG, G. J. 2010. Survey of orthodontists' attitudes and

experiences regarding miniscrew implants. J Clin Orthod, 44, 481-

KRAVITZ, N. D. & KUSNOTO, B. 2007. Risks and complications of

orthodontic miniscrews. American Journal of Orthodontics

Dentofacial Orthopedics,131, S43-S51.

MELSEN, B. & VERNA, C. Miniscrew implants: the Aarhus anchorage

system. Seminars in Orthodontics, 2005. Elsevier, 24-31.

MIYAWAKI, S., KOYAMA, L, INOUE, M., MISHIMA, K.,

SUGAHARA, T. & TAKANO-YAMAMOTO, T. 2003. Factors

associated with the stability of titanium screws placed in the

posterior region for orthodontic anchorage. Am J Orthod

Dentofacial Orthop,124, 373-8.

MOTOYOSHI, M., UENO, S., OKAZAKI, K. & SHIMIZU, N. 2009a.

Bone stress for a mini-implant close to the roots of adjacent teeth-

D finite element analysis. International journal of oral

maxillofacial surgery,38, 363-368.

MOTOYOSHI, M., UENO, S., OKAZAKI, K. & SHIMIZU, N. 2009b.

Bone stress for a mini-implant close to the roots of adjacent teeth—

D finite element analysis. Int J Oral Maxillofac Surg, 38, 363-8.

MOTOYOSHI, M., YOSHIDA, T., ONO, A., SHIMIZU, N. J. I. J. O. O.

& IMPLANTS, M. 2007. Effect of cortical bone thickness and

implant placement torque on stability of orthodontic mini¬

implants. 22.

PAN, C. Y., CHOU, S. T., TSENG, Y. C., YANG, Y. H., WU, C. Y.,

LAN, T. H., LIU, P. H. & CHANG, H. P. 2012. Influence of

different implant materials on the primary stability of orthodontic

mini-implants. Kaohsiung J Med Sci, 28, 673-8.

PAPADOPOULOS, M. A., PAPAGEORGIOU, S. N. & ZOGAKIS, I. P.

Clinical effectiveness of orthodontic miniscrew implants: a

meta-analysis. J Dent Res,90, 969-76.

PAPADOPOULOS, M. A., TARAWNEH, F. J. O. S., ORAL

MEDICINE, ORAL PATHOLOGY, ORAL RADIOLOGY, &

ENDODONTOLOGY 2007. The use of miniscrew implants for

temporary skeletal anchorage in orthodontics: a comprehensive

review. 103, e6-el5.

PEREZ LUGO, M. 2018. Tratamiento de maloclusiones en el piano

vertical con microtornillos.

ROBERTS, W. E., ARBUCKLE, G. R. & ANALOUI, M. 1996. Rate of

mesial translation of mandibular molars using implant-anchored

mechanics. The Angle Orthodontist,66, 331-338.

STAHL, E., KEILIG, L., ABDELGADER, L, JAGER, A. & BOURAUEL,

C. J. J. O. O. O. F. D. K. 2009. Numerical analyses of biomechanical behavior of various orthodontic anchorage implants. 70.

YU, J.-H., LIN, Y.-S., CHANG, W.-J., CHANG, Y.-Z., LIN, C.-L. J. J. O. M. & ENGINEERING, B. 2014. Mechanical effects of micro-thread orthodontic mini-screw design on artificial cortical bone. 34, 49-55.

Downloads

Published

2023-04-30

Issue

Section

Articles

How to Cite

Abdulhussein, Z., Abbood Al-Maliky, M., Haleem, R., Ehsan, R., Shihan, T., & ADILBAYEV, Z. (2023). Mini screw Application in Contemporary Orthodontic a Review of Literature. History of Medicine, 9(2). http://13.200.237.241/HOM/index.php/medicine/article/view/548